Wavetronix SmartSensor Advance Extended Range (SS-200E) - Use Instrukcja Użytkownika Strona 87

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 148
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 86
86 CHAPTER 7 CHANNELS-ALERTS-ZONES
Figure 7.21 – Adjusting Zones for Advance (left) and Advance Extended Range (right)
Speed (mph) and ETA (s)
In addition to range, zone detections can also be ltered by speed and by the estimated time
of arrival to the stop bar. Click anywhere in the Speed or ETA area and the Edit Basic Filters
screen will appear (see Figure 7.22).
Figure 7.22 – Edit Basic Filters Screen
Edit the min and max values in the speed lter to set the range of qualied speeds. e min-
imum speed value is 1 mph (2 kph) and the maximum speed value is 100 mph (161 kph).
On the previous window, check the box to the le of the Speed label to enable the speed
lter (only speeds within the range will activate zone outputs); uncheck the box to disable
the speed lter (all speeds will activate zone outputs).
Edit the min and max values in the ETA lter to set the range of qualied ETAs. e mini-
mum ETA value is 0.1 seconds and the maximum ETA value is 25.4 seconds. If you try
to raise the max ETA value above 25.4, the lter will be set to INF, which will accept any
vehicle with an estimated time of arrival greater than the minimum.
On the previous window, check the box to the le of the ETA label to enable the ETA lter
(only ETAs within the range will activate zone outputs); uncheck the box to disable the ETA
lter (all ETAs will activate zone outputs).
Qualified Count
A qualied detection is a detection in a zone that meets the specied range, speed and ETA
lters. e SmartSensor Advance provides two very powerful detection qualication lters:
Przeglądanie stron 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 147 148

Komentarze do niniejszej Instrukcji

Brak uwag