Wavetronix SmartSensor Advance Extended Range (SS-200E) - Use Instrukcja Użytkownika Strona 61

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 148
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 60
60 CHAPTER 5 SENSOR SETTINGS
Note
If you are using a Click communication device, the baud rate for the sensor and the
Click device must be the same. Port 2 is designated as the data bus and is normally
left at 9600 bps in order to match the default setting on a Click 112/114 card. If you
change this baud rate on the sensor, you will also need to change it on the rack card.
Response Delay – is is used to congure how long the sensor will wait before re-
sponding to a message received. is is useful for some communications devices that
are unable to quickly change transmission direction. e default value is 4 milliseconds
for ports 1 and 2.
Remove Multi-drop Prefix – You will only need to turn this switch ON if you are using
a device that does NOT support the use of a multi-drop prex (i.e. Click 100).
Przeglądanie stron 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 147 148

Komentarze do niniejszej Instrukcji

Brak uwag