74 APPENDIX CLICK 340/341/342 MANAGED SWITCHES
Test intensity 3, criterion B
Test intensity 2, criterion B
Noise immunity according to EN61000-4-3
(IEC1000-4-3) (electromagneticfields)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN61000-4-4
(IEC1000-4-4) (burst)
Data lines:
Power supply: Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 3, criterion B
Noise immunity according to EN61000-4-5
(IEC1000-4-5) (surge)
Data lines:
Power supply: Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 1, criterion B
Noise immunity according to EN61000-4-6
(IEC1000-4-6) (conducted)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Table A.4 – Conformance With EMC Directives