CHAPTER 4 WEB-BASED MANAGEMENT 31
SNMP Configuration Menu
e SNMP Conguration menu is used to display or modify user-specic device data, e.g.,
location, device name or function (see Figure 4.6).
Figure 4.6 – SNMP Configuration Web Page
e Trap Conguration part of the table is used to view or modify the IP addresses of the
two trap receivers. It is also used to activate/deactivate the Send traps function.
Software Update Menu
e Soware Update menu is used to view or modify the parameters for a soware update
and to trigger the update (see Figure 4.7).
Figure 4.7 – Software Update Web Page
Executing the Firmware/Software Update
e device must have valid IP parameters so that the rmware can be updated. You also
need a functional TFTP server.
e following steps are required to update the soware (see Figure 4.8):
1 Save the selected rmware/soware in the download directory of your TFTP server.
2 Start the TFTP server.
3 Start the WBM of the switch and call the Soware Update page (General Congura-
tion/Soware Update).
4 Enter the IP address of the TFTP Server in the TFTP Server IP Address eld.