CHAPTER 7 SYSTEM PAGE 91
Consecutive Failures Error Threshold – Shows the number of consecutive failed con-
nection attempts that need to occur for the status to change to “Error.
Recent Data Interval Expiration – Shows the number of collection interval time peri-
ods that can pass before the recent data is expired. is means that if a sensor has a col-
lection interval of 30 seconds (and an interval expiration setting of 3) and the Collector
is not able to retrieve data from that sensor for over 90 seconds then the recent data
will expire. When a sensor does not have valid recent data, Collector will not display
data for that sensor on either the Sensors page, the Sensor Cong page, the TMDD
export, or recent data table. Whether a sensor has recent data or not has no eect on
sensor status.
Timer Settings
e Timer Settings section allows you to control when Collector downloads the current
conguration from each sensor, and to sync the onboard sensor clock with the current
server time (see Figure 7.10).
Figure 7.10 – Timer Settings
e Timer Settings section contains two automatic timers, which run on a xed schedule,
as well as a time synchronization control. Below is a list and description of the timer setting
options:
Update Config Timer – Runs an Update Conguration job for every sensor registered
in Collector and retrieves and saves the current conguration to the Collector data-
base. Selecting the Update Cong Timer checkbox will toggle the automatic opera-
tions. e intervals will normally default to every 360 minutes (6 hours) and have a
minimum of 10 minutes. e Next Run eld will show the next scheduled run based
on the current interval. An error alert will be displayed if the entered interval is invalid.
Synchronize Clock Timer – Runs a Sync Time job for every sensor registered in Col-
lector and changes the onboard system time for each sensor to the time on the Collec-
tor server. Selecting the Synchronize Clock Timer checkbox will toggle the automatic
operations. e intervals will normally default to every 360 minutes (6 hours) and have
a minimum of 10 minutes. e Next Run eld will show the next scheduled run based
on the current interval. An error alert will be displayed if the entered interval is invalid.